Meizhengbio's E-commerce Website: www.mzfoodtest.com
首页 Home Product Veterinary Drug Residues Gentamicin ELISA Test Kit

Gentamicin ELISA Test Kit

Analyte:Antibiotic Residue

Samples:Milk

Specification
96 Test/Kit
Product introduction
Summary

Gentamicin (GEN) is an aminoglycoside antibiotic, which mainly acts on Gram-negative bacteria. Because of its wide antibacterial spectrum, good curative effect and low price, it is widely used in veterinary clinics and animal feed additives. However, the effective concentration of GEN serum is very similar to the toxic concentration, and the safety range is small. It is prone to toxic and side effects during its application. In particular, the irregular use of large doses can easily lead to excessive GEN residues in animal foods, posing a hazard to human health. The damage to the brain nerves, hearing and kidneys is severe. Existing methods for detecting gentamicin, such as chromatography or chromatography-mass spectrometry, have complicated sample preparation, expensive equipment, complicated operations, and time-consuming. Using the gentamicin ELISA kit can quickly and accurately analyze the gentamicin residue in the sample.

This kit is a test product developed by the application of ELISA technology. The operation time is shorter than 45 minutes, which can minimize the operation error and work intensity.

 

Intended Use

The estriol ELISA Kit is intended for the quantitative analysis of estriol in commodities such as raw milk.






Available Products

P/N      Sensitivity                                             Sample                                                      
SC00460.2μg/kg              milk 


Precautions
1. Adhere to the instructions of test procedures. Do not run more than 8 tests at one time. 2. Store test kits at 2-8˚C when not in use, and do not use the kits beyond the expiration date. 3. Please don’t touch the membrane on the strips. 4. Remove microwell sealer slightly to prevent the powder from being released from the wells. 5. The sample to be tested must be a homogeneous liquid which cannot be agglomerated, fermented, rancid precipitated, etc., and cannot be colostrum. 6. Avoid direct sunlight and direct blows during testing. 7. Do not re-use pipette tips, test strips or microwells. 8. The unsealed microwells should be used within 1 hour. 9. Do not take tap-water, distilled water or deionized water as the negative control. 10. This test method is just used for rapid screening purpose, if positive results are occurred, please verify them by a quantitative method. 11. Considering that all materials, containers and devices exposed to the sample are contaminated with harmful substance,please wear protective gloves and safety glasses while using the kit. 12. The components in this test kit have been quality control tested as a standard batch unit. Do not mix components from different lot numbers. 13. Any problem encountered during usage, please contact with the supplier.
More Products
Leaving a message
XML 地图