Zearalenone Quantitative Rapid Test Kit

Analyte:Mycotoxin

Samples:Grain,feed raw material,some finished feed products.

Specification
96T/Kit
Product introduction
Summary

The mycotoxin zearalenone is formed by fungi of the genus fusarium and mainly affects corn, wheat, sorghum, barley and rye. Zearalenone is a phytohormone which displays, apart from its anabolic properties, mainly estrogenic effects. Because of its estrogenic properties, zearalenone may induce fertility disorders in animals with clinical signs of hyperestrogenism – an aspect of a disease which although reported mainly in hogs, is described in other species such as cow, horse and sheep.

Intended Use

The kit is a one-step lateral flow immunochromatographic assay that determines a quantitative level for the presence of zearalenone and is intended for use in grains, feed materials and feed products. This method is suitable for the rapid on-site test.

Available Product

P/N                         Sensitivity                  LOD                         Sample

JC0688                    -                                 0-500ppb                Grain,feed raw material,some finished feed products.

Precautions
1. Adhere to the instructions of test procedures. 2. Store test kits at 4-30˚C when not in use, and do not use the kits beyond the expiration date. 3. Please don’t touch the membrane on the strips. 4. Remove microwell sealer slightly to prevent the powder from being released from the wells. 5. Avoid direct sunlight and direct blows during testing. 6. Do not re-use pipette tips, test strips or microwells. 7. The unsealed microwells should be used within 1 hour. 8. This test method is just used for rapid screening purpose; if positive results are occurred,please verify them by a quantitative method. 9. Methanol/ Ethanol are flammable. Caution must be taken in its use and storage. 10. Please avoid direct sunlight or blowing when testing. 11. Do not take tap-water, distilled water or deionized water as a negative control. 12. Considering that all materials, containers and devices exposed to the sample are contaminated with toxins, please wear protective gloves and safety glasses while using a kit. 13. The components in this test kit have been quality control tested as a standard batch unit. Do not mix components from different lot numbers. 14. If the sample extract is too alkaline (pH>9) or acid (pH<5), please adjust the pH value of the sample extract to be 6.0-8.0 by using NaOH or HCl (2.0 mol/L) before dilution. 15. Any problem encountered during usage, please contact with the supplier.